Part Number Hot Search : 
LLST270 45027 150MC C3843 MBR1635 25081 4570A TDA1190
Product Description
Full Text Search
 

To Download C101024060 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specifications are subject to change without notice (25.10.99) 1 plug output time ranges supply: 24 vac/dc supply: 120 vac supply: 220 vac circular spdt 0.15- 6 s c 118 024 006 c 118 120 006 c 118 220 006 8 pin 1.5 - 60 s c 118 024 060 c 118 120 060 c 118 220 060 15 - 600 s c 118 024 600 c 118 120 600 c 118 220 600 circular 0.15- 6 s c 111 024 006 c 111 120 006 c 111 220 006 11 pin 1.5 - 60 s c 111 024 060 c 111 120 060 c 111 220 060 15 - 600 s c 111 024 600 c 111 120 600 c 111 220 600 circular dpdt 0.15- 6 s c 218 024 006 c 218 120 006 c 218 220 006 8 pin 1.5 - 60 s c 218 024 060 c 218 120 060 c 218 220 060 15 - 600 s c 218 024 600 c 218 120 600 c 218 220 600 circular 0.15- 6 s c 211 024 006 c 211 120 006 c 211 220 006 11 pin 1.5 - 60 s c 211 024 060 c 211 120 060 c 211 220 060 15 - 600 s c 211 024 600 c 211 120 600 c 211 220 600 plug output time ranges supply: 24 vac/dc supply: 120 vac supply: 220 vac circular spdt 0.15- 6 s c 108 024 006 c 108 120 006 c 108 220 006 8 pin 1.5 - 60 s c 108 024 060 c 108 120 060 c 108 220 060 15 - 600 s c 108 024 600 c 108 120 600 c 108 220 600 circular 0.15- 6 s c 101 024 006 c 101 120 006 c 101 220 006 11 pin 1.5 - 60 s c 101 024 060 c 101 120 060 c 101 220 060 15 - 600 s c 101 024 600 c 101 120 600 c 101 220 600 circular dpdt 0.15- 6 s c 208 024 006 c 208 120 006 c 208 220 006 8 pin 1.5 - 60 s c 208 024 060 c 208 120 060 c 208 220 060 15 - 600 s c 208 024 600 c 208 120 600 c 208 220 600 circular 0.15- 6 s c 201 024 006 c 201 120 006 c 201 220 006 11 pin 1.5 - 60 s c 201 024 060 c 201 120 060 c 201 220 060 15 - 600 s c 201 024 600 c 201 120 600 c 201 220 600 timers mono-function, plug-in, sym- metrical, on/off miniature recyclers up to 600 s (10 min) covering 3 individual time ranges. optional on- or off- time period first. this eco- nomical relay is often used in lighting systems such as ad- vertising signs, etc. function output type power supply time range ? time ranges: 0.15 s to 600 s ? automatic start ? c .0.: starts with off-time c .1.: starts with on-time ? knob-adjustable time within range ? oscillator-controlled time circuit ? repeatability deviation: 1% ? output: 10 a spdt or 8 a dpdt relay ? plug-in type module ? scantimer housing ? led-indication for relay on ? ac or dc power supply symmetrical recycler types c 101, c 201, c 108, c 208, c 111, c 211, c 118, c 218 ordering key product description type selection, off-time period first type selection, on-time period first c 108 024 600
2 specifications are subject to change without notice (25.10.99) time ranges 0.15- 6 s 1.5 - 60 s 15.0 - 600 s time range accuracy 0 to +10% on max. min. actual time min. set time repeatability deviation 1% time variation within rated power supply 0.05%/v and ambient temperature 0.2%/c reset power supply interruption min. time and/or relay 250 ms c 108, c 208, c 118, c 218 c 101, c 201, c 111, c 211 c 108, c 101, c 118, c 111 c 208, c 201, c 218, c 211 output spdt relay dpdt relay basic electrical insulation 250 vac (rms) (contact/electronics) 250 vac (rms) (contacts/elec., contact/contact) contact ratings (agcdo) (micro gap) (micro gap) resistive loads ac 1 10 a/250 vac (2500 va) 8 a/250 vac (2000 va) dc 1 1 a/250 vdc (250 w) 0.4 a/250 vdc (100 w) or 10 a/25 vdc (250 w) 4 a/25 vdc (100 w) small inductive loads ac 15 2.5 a/230 vac 2.5 a/230 vac dc 13 5 a/24 vdc 5 a/24 vdc mechanical life 3 30 x 10 6 operations 3 30 x 10 6 operations electrical life ac 1 3 2.5 x 10 5 operations (at max. load) 3 2.5 x 10 5 operations (at max. load) operating frequency 7200 operations/h 7200 operations/h insulation voltages rated insulation voltage 3 2.0 kvac (rms) (contact/electronics) 3 2.0 kvac (rms) (contact/electronics) rated transient protection volt. 4 kv (1.2/50 s) (contact/electronics) (iec 60664) 4 kv (1.2/50 s) (contact/electronics) (iec 60664) power supply ac types installation cat. iii (iec 60664) rated operational voltage through pins 2 & 10 220 220 vac + 15/- 20%, or pins 2 & 7 45 to 65 hz 120 120 vac + 15/- 20%, 45 to 65 hz 024 24 vac + 15/- 20%, 45 to 65 hz dropout tolerance 3 10 ms rated insulation voltage none rated transient protection volt. 4 kv (1.2/50 s) @ 220 vac 2.5 kv (1.2/50 s) @ 120 vac 800 v (1.2/50 s) @ 24 vac (line/neutral) power supply dc type installation cat. iii (iec 60664) rated operational volt. 024 24 vdc + 15/- 20% (pin 2 pos.) rated insulation voltage none rated transient protection volt. 800 v (1.2/50 s) consumption ac supply 60 ma @ 50 hz/70 ma @ 60 hz dc supply 1 w power on delay 200 ms power off delay 3 250 ms indication for output on led. red environment degree of protection ip 20 b pollution degree 2 (iec 60664) operating temperature -20 to +50c (-4 to +122f) storage temperature -50 to +85c (-58 to +185f) weight 85 g approvals ul, csa time specifications output specifications supply specifications general specifications
specifications are subject to change without notice (25.10.99) 3 example 1 (types c .0.) off-time period first the time period starts when power supply is applied. at the end of the first set time period, the relay operates. at the end of the second set time period (equal to the first), the relay releases. this sequence is repeated un- til power supply is interrupted. if power supply is disconnect- ed, the time is reset and a re- covery period of 250 ms sho- uld be allowed before the re- cycler is ready for reactiva- tion. example 2 (types c .1.) on-time period first the relay operates and the time period starts immediately when power supply is applied. at the end of the first set time period, the relay releases. at the end of the second set time period (equal to the first), the relay operates again. this sequence is repeated with equal intervals until pow- er supply is interrupted. if power supply is interrupted, the time is reset and a recove- ry period of 250 ms should be allowed before the recycler is ready for reactivation. c 108, c 208, c 118, c 218 c 101, c 201, c 111, c 211 power supply c 101, c 111 c 201, c 211 power supply c 108, c 118 c 208, c 218 knob-adjustable on scale in seconds. sockets ? s 408, s 411 hold down spring ? hf mounting rack sm 13 socket cover bb4 potentiometer lock pl 1 for further information refer to "accessories". power supply example 1: relay on example 2: relay on mode of operation wiring diagrams time setting accessories operation diagram


▲Up To Search▲   

 
Price & Availability of C101024060

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X